Specifications
- Primary Application: 2M (E1) bit error rate testing
- Bit Rate: 2048 kb/s ±50 ppm
- Interfaces: 75 Ω unbalanced & 120 Ω balanced
- Test Modes: In-service and out-of-service testing
- Framing: Framed and unframed
- Frame Types: PCM30, PCM30CRC, PCM31, PCM31CRC
- Line Code: HDB3
Test Patterns:
- Random: 2¹⁵–1, 2¹¹–1
- Fixed: 1111, 0000, 1010
- Error Insertion: Single error and fixed-rate (10⁻³, 10⁻⁶)
- Monitoring: Timeslot voice monitoring
- Alarm Detection: Signal loss, AIS, frame loss, CRC error, remote alarm
- Interfaces: RS-232, USB
- Display: Backlit LCD with menu-driven operation
- Data Storage: Up to 90 result sets
- Battery: Built-in Ni-MH rechargeable batteries (≈8 hours operation)
- Charging: Built-in fast charger (≈4.5 hours)
- Form Factor: Rugged handheld for field use
- Weight: ~700 g
Packing List
- Body FHE-1
- Battery 6 Pcs
- Adapter AC/DC 12V 2A
- Cable Rj45 Tx Rx
- Cd Manual and Manual Book
- Adapter Connector DB9 To Jack 3m5 mm
- Softcase